Parameter | Characteristic | DC Charger CCS2 | ||||
Power | Rated Power | 15 kW | 30 kW | 60 kW | 120 kW | 240 kW |
Number of output | Single Gun | Single or Dual Gun | Single or Dual Gun | Single or Dual Gun | Dual Gun | |
Output current (per gun) | 40A max | 80A max | 150A max | 200A Max | 200A Max | |
Input voltage | 415 Vac (±10%), 50 Hz Three phase | |||||
Output Charging Outlet | CCS2 | |||||
Output voltage | 150-1000V DC | |||||
Power Factor | ≥0.98 | |||||
Efficiency | ≥95 | |||||
User Interface | Display | 7” TFT LCD with touch | ||||
Push Button | Emergency Stop | |||||
User Authorization | RFID + OCPP v1.6 | |||||
Environment | Ambient Temperature | -20⁰C to 55⁰C | ||||
Storage Temperature | -40⁰C to 70⁰C | |||||
Altitude | <2000 m | |||||
Humidity | <95%, Non condensing | |||||
Communication | External | WiFi, RS485, LAN/4G + OCPPv1.6 | ||||
Metering and Billing | Available | |||||
Charging Operation | RFID Card/ Scan QR Code/Mobile App | |||||
Protection | Input/Output protection | Over/Under voltage protection, Overload protection, Short circuit protection, Current leakage protection, Grounding protection, Surge protection, Over/Under temperature Protection | ||||
Protection level | IP54 | |||||
Cooling | Forced Air Cooling | |||||
Miscellaneous | As per | IEC 61851-1:2017 , IEC 61851-21-2 | ||||
Safety | CE | |||||
Certification | ARAI | |||||
Mounting | Wall/ Stand Mount | Wall/ Stand Mount | Floor Mount | Floor Mount | Floor Mount |