Parameter | Characteristic | AC Charger – Single Socket | AC Charger – Triple Sockets |
Input Power | Rated Power | 3.3 kW | 10 kW |
Input voltage | 230V AC, Single phase | 415V AC, 3 phase | |
Output Power | Number of Output | 1 | 3 |
Output current | 0-16A per output | 0-16A per output | |
Output Charging Outlet | IEC 60309 | 3 x IEC 60309 | |
Output voltage | 230V AC | 230V AC | |
User Interface and Controls | Display | Optional | 4.3″HMI LCD Display |
Push Button | Emergency Stop | ||
User Authentication | RFID + OCPPv1.6 | ||
Environment | Ambient Temperature | -20⁰C to 55⁰C | |
Storage Temperature | -40⁰C to 70⁰C | ||
Altitude | <2000 Mtr | ||
Humidity | <95%, Non condensing | ||
Communication | External | WiFi, RS485, LAN/4G + OCPPv1.6 | |
Metering and Billing | Available | ||
Charging Operation | Swipe card / Scan code / APP based authentication | ||
Protection | Input/ Output protection | Over/Under voltage protection, Overload protection, Short circuit protection, Current leakage protection Grounding protection, Surge protection, Over/Under temperature | |
Mechanical Protection | IP54 | ||
Cooling | Natural Cooling | ||
Regulation | As per | IEC 61851-1:2017, IEC 61851-21-2 | |
Safety | CE | ||
Certification | ARAI | ||
Mounting | Wall / Pole Mount |